Logo
Logo

Acorn BASyC® Digital System with Multiple Master Mixing Valves

Find A Representative
Model ABMMV Series
UPC
No Lead  - Federal Public Law 111-380
ASSE 1017
CSA B125.3
Installation Instructions
BASyC® Installation & Maintenance Guide (pdf)
View
Submittal
Submittal BASyC System with MV Valves (pdf)
View
Model ABMMV Series

Acorn BASyC® Digital System with Multiple Master Mixing Valves

Acorn BASyC® digital mixing valve and monitoring system is ideal for any facility’s recirculating domestic hot water system where optimal bather safety is desired. It provides distributed control and monitoring of Acorn Controls® MV17 mixing valves and a wide variety of temperature, pressure, and flow sensors.

Key Benefits

  • Reduces energy consumption by 50%
  • Prevents scalding, burns, and thermal shock
  • Inhibits Legionella
  • Balances erratic water temperatures
  • Provides safe and comfortable water temperature in showers, tubs, sinks, and emergency equipment

Utilizing Niagara software, the Acorn BASyC® can aggregate information (real-time data, history, alarms, etc.) from an array of sensors. Acorn BASyC® can connect to a facility’s local area network and/or the existing BAS via industry-standard network protocols.

Features

  • Acorn ConTrols® Electronically Actuated Thermostatic Mixing Valve and Multi-Valve Assemblies.
    • Able to control any combination of up to (4) MV17 mixing valves in one or two separate temperature loops.
    • Valves certified by IAPMO to ASSE 1017 standards with Hi/Low performance.
    • Maintains thermostatic control of set point during power, temperature probe, valve or actuator failure.
    • Provides Redundant Control.
  • Honeywell/Niagara hardware/software.
    • The industry standard in building automation.
    • Non-proprietary platform.
    • Estimated flow and energy usage; no need for a costly flow meter.
    • Plug and play makes start-up quick and simple.
  • Acorn ConTrols® unique control algorithm and system design provide control that exceeds the requirements of ASSE 1017.
  • Effectively shuts off hot or cold water during supply failure.
  • Alarms and Alerts with relay outputs and e-mail notifications if connected to the facility's Ethernet.
  • Expandable.
    • 18 (10 digital, 8 analog) programmable outputs to drive a wide variety of devices.
    • 16 universal inputs will accept a wide variety of input sensors.
    • Up to 100 data points.
  • Programmable/automated sanitization mode helps to minimize a facility's Legionella risks and when combined with Acorn ConTrols® valves, simplifies the process.
  • Sensors and control devices are labeled and keyed to eliminate potential mistakes.
  • Water-tight connectors improve sensor and control device reliability and make replacements easier.
  • Primary Ethernet Adapter allows connection to Acorn BASyC® via the facilities LAN.
  • The secondary Ethernet Adapter is independent of the primary LAN or BAS and is reserved for the support of the Acorn BASyC® system.
  • Password protection allows levels of secure access.
  • Sanitization includes a 'safe start' feature that automatically goes back to the previous setting upon completion.
  • Sanitization screen logs times and temperatures for a record of the process with e-mail acknowledgment.
  • History retention for data points allows customizable reports that can be saved and/or exported.
  • Each controller is able to communicate via two separate RS-485 networks with no external gateway.
  • Numerous RS-485 communication protocols are available (BACnet, Modbus or user-specified).

Downloads

Resource Type
Title
Description
Answers
File Size
Action
PDF icon
Installation Instructions
PDF icon
BASyC® Installation & Maintenance Guide (pdf)
BASyC® Installation & Maintenance Guide (pdf)04 MB
PDF icon
Submittals
PDF icon
Submittal BASyC System with MV Valves (pdf)
Acorn Controls BASyC™ Digital Mixing Valve and Monitoring System0992 KB
ZIP icon
BIM/CAD/Revit
ZIP icon
ABMMV-4 BASyC Valve System (dwg/zip)
BASyC® Digital System with Multiple Master Mixing Valves including MV17-4 [ABMV-4400-2-G0-22-00-00-B-10-T-N; ABMV-4500-2-G0-00-00-00-C-10-T-N]04 MB
RFA icon
BIM/CAD/Revit
RFA icon
ABMMV-5 BASyC Valve System (rfa/zip)
BASyC® Digital System with Multiple Master Mixing Valves including MV17-5 [ABMV-5550-3-00-00-00-80-C-L-N; ABMV-5550-3-30-H0-00-00-00-0-00-0, ABMMV-5500-2-00-00-00-00-0-00-T-N, ABMMV-5500-2-H0-20-00-00-B-10-T-N]05 MB
RFA icon
BIM/CAD/Revit
RFA icon
ABMMV-4 BASyC Valve System (rfa/zip)
BASyC® Digital System with Multiple Master Mixing Valves including MV17-4 [ABMV-440-2-X0-20-00-80-C-10-L-N-SP; ABMV-4400-2-G0-22-00-00-B-10-T-N; ABMV-4500-2-30-00-00-00-0-00-10-SP; ABMV-4500-2-G0-00-00-00-C-10-T-N]08 MB
RFA icon
BIM/CAD/Revit
RFA icon
ABMMV-5 BASyC Valve System (dwg/zip)
BASyC® Digital System with Multiple Master Mixing Valves including MV17-5 [ABMMV-5500-2-00-00-00-00-0-00-T-N, ABMMV-5500-2-H0-20-00-00-B-10-T-N]02 MB
PDF icon
Brochures/Flyers
PDF icon
Kwik Ship® Brands: Acorn ConTrols® (pdf)
Save time and money with Acorn ConTrols® Kwik Ship products, with many items shipped fully or partially assembled and stock replenished weekly.0737 KB
PDF icon
Brochures/Flyers
PDF icon
Acorn ConTrols® System Flyer (pdf)
See how Acorn ConTrols® valves and systems work together to regulate the water flow through an entire building.01 MB
PDF icon
Brochures/Flyers
PDF icon
Acorn ConTrols® Sales Brochure (pdf)
Acorn ConTrols® manufactures and distributes a complete line of thermostatic mixing, balancing, pressure regulating, and check valves to handle water temperature, pressure, and flow in a building.05 MB
PDF icon
Brochures/Flyers
PDF icon
Acorn ConTrols® Technical Brochure (pdf)
Detailed specs and descriptions for the complete Acorn ConTrols® line of mixing, tempering, balancing, check, and pressure reducing valves.04 MB
PDF icon
Brochures/Flyers
PDF icon
MV17 Master Mixing Valve Flyer (pdf)
To protect against Legionella, the MV17 master mixing valve stores water at 140°F or higher before delivering it to the distribution system. Tempering valves then provide a final adjustment at the point of use to achieve the desired water temperature.0710 KB
PDF icon
Brochures/Flyers
PDF icon
Sanitization Override Flyer (pdf)
Sanitization Override Flyer (pdf)0447 KB
PDF icon
Brochures/Flyers
PDF icon
BASyC Flyer (pdf)
BASyC Promotional Flyer0816 KB
PDF icon
Brochures/Flyers
PDF icon
MGI Corporate Brochure (pdf)
Comprised of 28 divisions spanning diverse markets, Morris Group International designs, engineers, and manufactures products with precision to meet today’s construction and installation trends.07 MB

Specifications

BrandAcorn ConTrols®
Valve Size3/4" NPT Inlet & 1" NPT Outlet, 1" NPT Inlet & 1-1/4" NPT Outlet, 1-1/4" NPT Inlet & 1-1/2" NPT Outlet, 1-1/2" NPT Inlet & 2" NPT Outlet
ConnectionsNCT
Featured ValveMV17 Series
Product TypeThermostatic Balancing Valve, BASyC® Digital Valve Monitoring System
ComplianceUPC, No Lead - Federal Public Law 111-380, ASSE 1017, CSA B125.3

Models

ABMMV-__ __ __ __-__-__ __-__ __-00-__ __-__-__ __-__-__-__

Valve Sizes 2 | MV17-2 (45 GPM); 3 | MV17-3 (90 GPM); 4 | MV17-4 (150 GPM); 5 | MV17-5 (225 GPM)

Number of Valves 2 | Two Valves; 3 | Three Valves; 4 | Four Valves;

Return Pipe Size 0 | No Return Pipe; C | 1/2"; D | 3/4"; E | 1"; F | 1-1/4"; G |1-1/2"; H |2"

Recirculation Pump, Pump Control, Zone One & Zone Two 0 | No Pump and No Pump Control Pump; 1 | with AquaStat Control; 2 | Pump and Pump Control Relay Pump; 3 | with No Control; 4 | No Pump, Include Pump Control Relay

Automatic Balancing Valves00 | No Valves

Flow/BTU Data - Zone One and Zone Two 0 | Do Not Include; 8 | Calculated BTU and Flow Data; 9 | Flowmeter with Flow/BTU Data

Inlet Temperature and/or Pressure Sensors 0 | Standard Outlet Sensor(s) only; B | Inlet Temp. Sensors; C | Inlet Temp. and Inlet/Outlet Press. Sensors

Return Temp Data - Zone One and Zone Two 0 | Do Not Include; 1 | Sensor on Return Line at Recirc Pump; 3 | Lead/Lag Pump Control

Touchscreen Display0 | Do Not Include; T | Include

BAS Protocol Adapter 0 |Do Not Include; M |BACNet I/P; N | BACNET MTSP; P | Modbus MSTP; R | Lonworks MSTP; S | OBIX

Special Feature Blank | No Special Feature; SP | Special Feature